Gas Generator
10–1000 kW Gas Generator Sets for Commercial, Industrial and Distributed Power
Weifang Bofa Power Equipment Co., Ltd. manufactures gas generator sets from 10 kW to 1000 kW for industrial facilities, commercial buildings, agricultural projects and distributed energy systems.
With flexible OEM customization options, we provide complete gas generator solutions including engine selection, alternator matching, controller configuration, enclosure design and project-specific documentation.
Comprehensive Gas Generator Range & Specifications
|
Specification |
Available Configuration |
|
Power Range |
10–1000 kW, with higher-capacity configurations available for specific projects |
|
Operation Duty |
Prime / Standby / Continuous |
|
Frequency |
50 Hz / 60 Hz |
|
Voltage |
Project-specific (110V – 480V, Single / Three Phase) |
|
Phase |
Three Phase (Single phase available upon request) |
|
Gas Type |
Natural Gas, Biogas, Landfill Gas, and applicable fuel gases |
|
Cooling System |
High-efficiency water-cooled configurations |
|
Controller System |
Manual / Automatic / AMF / Parallel Synchronization (DeepSea, ComAp, Smartgen) |
|
Installation |
Open Skid / Weatherproof Silent / Containerized |
|
Fuel System |
Configured with advanced gas trains according to gas supply conditions |
|
OEM / ODM |
Engine, alternator, enclosure, branding, and documentation fully customizable |
Standard Model Specifications
|
Model |
Rated power(kVA) |
Rated Voltage(V) |
Rated Frequency(Hz) |
Suitable fuel |
Configuration |
|
BF30NG |
30KVA |
230/400V |
50/60HZ |
Natural gas |
Silent/Open |
|
BF50NG |
50KVA |
230/400V |
50/60HZ |
Natural gas |
Silent/Open |
|
BF100NG |
100KVA |
230/400V |
50/60HZ |
Natural gas |
Silent/Open |
|
BF150NG |
150KVA |
230/400V |
50/60HZ |
Natural gas |
Silent/Open |
|
BF200NG |
200KVA |
230/400V |
50/60HZ |
Natural gas |
Silent/Open |
|
BF300NG |
300KVA |
230/400V |
50/60HZ |
Natural gas |
Silent/Open |
|
BF400NG |
400KVA |
230/400V |
50/60HZ |
Natural gas |
Silent/Open |
|
BF500NG |
500KVA |
230/400V |
50/60HZ |
Natural gas |
Silent/Open |
Engineering Note on Biogas & Landfill Gas Tolerance
Unlike pipeline natural gas, renewable gases can fluctuate in composition and may contain corrosive contaminants. Gas generator configurations for biogas and landfill gas should therefore be selected according to the actual fuel composition and the applicable engine specifications.

CH₄ (Methane Content)
Selected engine configurations can support methane concentrations down to CH₄ ≥ 40%, with dynamic air-fuel ratio control.

H₂S Resistance
Selected engine configurations can tolerate H₂S levels up to 200 ppm. Higher concentrations may require upstream gas treatment.

Siloxanes & Moisture Control
Multi-stage condensate traps and optional activated carbon scrubbers can help control moisture and siloxane-related deposits within the engine system.
Fuel Gas Types and Operational Considerations
Natural Gas Generators
Pipeline natural gas typically provides high methane content and a relatively stable supply, making it an ideal choice for continuous industrial operation, peak shaving, and commercial standby power.
Key Focus:
• Gas Train Safety: Equipped with reliable safety shut-off valves and comprehensive gas train protection.
• Inlet Pressure Control: Regulated gas inlet pressure, typically 10–300 kPa depending on the engine model.
• Engine Control: Advanced anti-knock control parameters precisely matched to the selected engine.
Typical Applications: Manufacturing plants, data center backup, municipal utilities, and urban distributed power generation.
Biogas and Renewable Gas Generators
Biogas produced from anaerobic digestion, agricultural livestock waste, or municipal wastewater treatment contains varying levels of methane, carbon dioxide, moisture, and corrosive trace elements.
Key Focus:
• H₂S Corrosion Control: Specialized measures to mitigate internal corrosion caused by hydrogen sulfide.
• Moisture Management: Strict control of moisture condensation within the fuel system manifold.
• Air-Fuel Ratio Adjustment: Dynamic adjustment capabilities to accommodate seasonal or biological shifts in methane concentration.
Upstream Gas Treatment Guidance: Where contaminant levels exceed strict manufacturer thresholds, our engineering team integrates upstream gas treatment solutions:
• Moisture separators and gas chillers
• Activated carbon and iron sponge H₂S scrubbers
Components & System Configuration
|
Component / System |
Standard Configuration |
Project-Specific Options |
|
Gas Engine |
Engine matched to output and gas type |
Natural gas, biogas, landfill gas |
|
Alternator |
Brushless, three-phase |
Stamford, Leroy Somer, custom voltage/frequency |
|
Gas Train |
Filtration, pressure regulation, safety shut-off |
Booster, gas treatment, additional safety devices |
|
Control System |
Digital controller with engine and electrical monitoring |
DeepSea, ComAp, SmartGen, AMF, synchronization |
|
Cooling System |
Water-cooled radiator |
Heavy-duty or high-ambient configuration |
|
Exhaust System |
Exhaust manifold and silencer |
Low-noise silencer, customized routing |
|
Starting System |
Electric starter and battery set |
Heavy-duty starting system |
|
Fuel & Air System |
Engine-matched gas and air intake |
Gas booster, filtration, AFR control |
|
Electrical System |
Output breaker and protection |
ATS, synchronization and load sharing |
|
Enclosure |
Open skid or acoustic enclosure |
Containerized, low-noise, ventilation and fire protection |
|
Base Frame |
Steel skid with vibration isolation |
Custom dimensions and lifting points |
Gas Train & Fuel Safety Systems
Gas Filtration
Removes particulates and suspended contaminants before gas enters the pressure regulation system.
01
Pressure Regulation
Maintains gas pressure within the engine's specified operating range.
02
Safety Shut-Off Valves
Isolate the gas supply during emergency stops or detected system faults.
03
Leak Detection
Monitors gas leakage and supports automatic safety shutdown where required.
04
Moisture & Condensate Control
Helps prevent liquid accumulation in the gas manifold and fuel system.
05
Control, Monitoring, and Engine Protection
Engine Monitoring
Real-time monitoring of oil pressure, coolant temperature, exhaust temperature, boost pressure and other key parameters.
Fuel Safety Interlocks
Gas supply can be shut off in response to abnormal gas pressure, flame-out or detected gas leakage.
Parallel Operation
Digital controllers such as DeepSea, ComAp and SmartGen can support synchronization, automatic load sharing and multi-generator operation.
Customization, OEM / ODM Solutions, and Global Components
Core Partnerships
Compatible with world-renowned engine platforms, Stamford / Leroy Somer alternators, and ComAp / DeepSea control systems.
Mechanical & Electrical Adaptations
Custom skid designs, alternative alternator brands, specific system voltages, and specialized heavy-duty cooling packages engineered for high ambient temperatures.
Enclosure Engineering
Weatherproof, sound-attenuated acoustic enclosures (75 dB at 7 meters or lower) or custom ISO containers equipped with forced ventilation, fire suppression systems, and integrated control rooms.
Private Labeling & Documentation
Customer-specific color schemes, branded control panel overlays, localized user manuals, electrical wiring schematics, and complete factory compliance documentation (CE, ISO9001).
Step-by-Step Gas Generator Selection Guide
Calculate Electrical Load and Profile: Assess continuous operating loads, starting currents for large electric motors, and potential future load expansion.
Analyze Fuel Composition and Quality: Verify methane concentration, heating value, and potential corrosive contaminants (submitting a gas chromatography report is strongly recommended).
Verify Gas Supply Pressure and Flow: Confirm that the gas delivery pressure at the generator skids meets the minimum requirements of the pressure-regulating train.
Define Operating Duty: Specify whether the unit operates as prime power (continuous baseload) or standby backup.
Evaluate Environmental and Acoustic Constraints: Determine if the unit will be installed indoors, within a sound-attenuated enclosure, or inside an outdoor ISO container.

Factory Testing and Quality Inspection Protocols
Mechanical and Functional Runs
Comprehensive testing under simulated load conditions to verify governor response, vibration levels, and thermal equilibrium.
Electrical Verification
Output voltage regulation, frequency stability, insulation resistance testing, and harmonic distortion analysis.
Control and Safety Check
Verification of emergency shutdown sequences, alarm logic, automatic mains failure (AMF) response, and gas train valve seal integrity tests.
Documentation Verification
Cross-checking serial numbers, nameplates, accessory inventories, and export packaging integrity against project specifications.
Manufacturing Experience & Export Capability
Established Manufacturer
Established in 2011 in Weifang, Shandong, with convenient access to Qingdao Port. 14+ years of experience in the development, manufacturing and technical service of diesel and gas generator sets.
Full Power Range
Generator sets from 10 kW to 3000 kW across our product range, with gas generator sets available according to project requirements.
Production Standards
Manufactured and tested according to ISO 8528 and GB/T 2820-97 standards. The company is certified to ISO 9001 and ISO 14001, with CE-certified products for applicable European export requirements.
Export Markets
Products are exported to Southeast Asian markets including the Philippines, Indonesia, Vietnam and Myanmar, with ongoing market development across Saudi Arabia, UAE, Qatar, Kuwait, Oman and Iraq.
FAQ
We're well-known as one of the best gas generator suppliers in China. With a professional production team, we are able to meet the needs of the majority of our customers. Please feel free to buy cheap gas generator for sale here from our factory. For price consultation, contact us.