Bofa Power supplies diesel standby generator sets from 10–3000 kW for industrial, commercial and infrastructure applications. Generator capacity, electrical configuration, fuel storage and control systems are selected according to the site's actual load and operating conditions.

 

The Need for Standby Power
 

Power interruptions can stop production, interrupt IT systems, disable HVAC and pumping equipment, and affect essential building services.

For facilities where these interruptions have operational or financial consequences, standby generation provides an independent source of power for designated loads during a utility failure.

Typical applications:

Manufacturing plants
Data centers
Commercial buildings
Hospitals and critical facilities
Infrastructure facilities

 

The Challenges

Load Profile
Identify which loads must remain operational and their actual running demand.

 

Motor Starting
Motors, pumps and compressors can require significantly higher current during startup.

Transfer Requirements

The ATS must coordinate correctly with the generator controller and facility distribution system.

Backup Runtime

Fuel capacity must correspond to the required operating duration and refueling conditions.

Installation Conditions

Ventilation, exhaust, ambient temperature, altitude and noise restrictions can affect the generator configuration.

 

Our Standby Power Approach

 

Load

Required standby capacity and essential load profile.

01

Electrical System

Voltage, frequency, phase and distribution requirements.

02

Operating Conditions

Motor starting characteristics, ambient conditions and expected runtime.

03

Installation

Indoor, outdoor, mobile or containerized installation.

04

Control

ATS, automatic start/stop, monitoring, synchronization or load sharing requirements.

05

 

What We Provide
 

Diesel Generator Sets

Generator sets for standby applications across a wide range of facility sizes and load requirements.

Engine Options

Depending on the required output and project specification:

Cummins | Perkins | Volvo | Yuchai | Weichai | SDEC | MTU

 

Generator Configurations

Configuration

Typical Use

Open Type

Dedicated generator rooms

Silent Type

Noise-sensitive locations

Containerized

Outdoor and remote installations

Mobile Type

Temporary or relocatable backup power

 

System Components

 

Generator Set

Provides the standby electrical source.

ATS

Transfers designated loads between utility and generator power.

Generator Controller

Monitors operating parameters and manages automatic start/stop functions.

Fuel System

Provides the required fuel storage and supply for the specified runtime.

Cooling & Exhaust System

Maintains operating temperature and safely manages exhaust gases.

Enclosure

Provides acoustic and weather protection where required.

 

Factory Testing
 

Testing Before Shipment

Each generator set can be inspected and tested according to the agreed project requirements.

Engine Test

Starting, running and shutdown checks.

Electrical Test

Voltage, frequency, phase and electrical connections.

Controller Test

Alarm, monitoring and protection functions.

Load Test

Operation under an agreed electrical load.

Final Inspection

Mechanical assembly, wiring, fuel system, enclosure, accessories and documentation.

 

Get Your Standby Power Configuration

 

 

Send us your load information, electrical specifications and installation conditions. Our team can review the requirements and determine a suitable generator capacity and configuration.